Alliance Ground Power, LLC, manufactures a line of trailer-mounted engine-driven AC/DC ground power units which provide quality electrical power suitable for today’s sophisticated aircraft systems. These units meet or exceed Mil-STD-704F as well as all major airframe power quality specifications. 

The units are equipped with high quality Cummins or Deutz diesel engines and reliable AC 400 HZ Marathon generators.  A specially designed transformer-rectifier unit (Optional) provides high quality DC power for continuous operation as well as robust power to start the most difficult aircraft engines - even in extreme cold conditions. 

A state-of-the-art digital controller monitors engine sensors and assures power quality limits are not exceeded.  The control panel affords the operator a simple scroll-through menu of all the significant engine and output power parameters.  Monitoring of the engine includes oil pressure, coolant temperature, battery voltage, and total run time.  AC power monitoring includes voltage, current, and KVA of each phase, as well as frequency and total KVA. 

The controller provides warnings for a weak battery, low fuel level, low oil pressure, or similar maintenance activities.  If a shutdown occurs to protect the equipment, this event is captured and stored to help in determining the problem.  The event recorder stores engine starts/stops as well as run time.

Engine
·  Cummins or Deutz Tier III, 4 or 6 cylinder turbocharged, water cooled, Diesel powered.
·   Solid state governor.
·   AGM battery 


Alternator
·   Marathon Brushless single bearing, 100,000 hours TBO.
·   Output meets MIL-STD-704F 


Control Panel
·   state-of-the-art digital controller monitors engine sensors and assures power quality limits are not exceeded.
·   simple scroll-through menu of all the significant engine and output power parameters.
·    Monitoring of the engine includes oil pressure, coolant temperature, battery voltage, and total run time.
·    AC power monitoring includes voltage, current, and kVA of each phase, as well as frequency and total kVA.
·    Warnings for a weak battery, low fuel level, low oil pressure, or similar maintenance activities.
·    If shutdown occurs to protect the equipment, event is captured and stored.  Event recorder stores engine starts/stops as well as run time.
Unit Performance
·  115/200 VAC, 3 phase, 400 Hertz .8 PF
·  Available in continuous ratings from 40 kVA through 180 KVA.
·  125% Overload for 5 minutes.
·  Operating environment is -30 to +50 deg C, 1000 meters altitude.  Some models are derated at higher values.
·  Steel powder coated enclosure. 
·  Towbar activated brake.

Engine Protection
·   Low oil pressure shutdown.
·   High coolant temperature shutdown.
·   Low fuel shutdown.
·   Oil and fuel filters with water separator.
·   Over speed shutdown.
·   Emergency stop switch. 

Output Power Protection
·   Over frequency protection
·   Under frequency protection
·   Under/over voltage trip.
·   Safety interlock on cable assembly. 

Options
·  Transformer Rectifier for 28.5 VDC
·   Engine coolant heater 120Vac.
·   Skid mounted.
·  Position lights.